翻訳と辞書
Words near each other
・ Darjijari
・ Darju
・ Darjuneh
・ Darjuš Lavrinovič
・ Dark & Dirty Mile
・ Dark & Long
・ Dark & Wild
・ Dark 'N' Stormy
・ Dark (album)
・ Dark (broadcasting)
・ Dark (disambiguation)
・ Dark (surname)
・ Dark (video game)
・ Dark adaptation threshold
・ Dark Adapted Eye
Dark adaptor goggles
・ Dark Adrenaline
・ Dark Adventure
・ Dark Adventure Radio Theatre
・ Dark Age (band)
・ Dark Age (film)
・ Dark Age Ahead
・ Dark Age of Camelot
・ Dark Age of Reason
・ Dark Ages
・ Dark Ages (1991 video game)
・ Dark Ages (1999 video game)
・ Dark Ages (album)
・ Dark Ages (band)
・ Dark Ages (historiography)


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Dark adaptor goggles : ウィキペディア英語版
Dark adaptor goggles

Dark adaptor goggles (Red adaptation goggles) are used in the field of meteorology for either adapting the eyes to the dark prior to an observation at night or to aid with the identification of clouds during bright sunshine or glare from snow. The goggles are made with red-tinted plastic lenses. Although the goggles are designed to be worn indoors, some people find walking, especially up and down stairs, to be difficult. Such goggles or glasses are often used by pilots and weather observers to preserve their natural night vision.
For use at night the observer should put the goggles on about ten minutes prior to going outside. Once the observer is outside and away from major sources of light the goggles may be removed and the observer's vision should be adapted to the dark.
To help with the identification of clouds during the day the goggles should be put on just before the observer goes outside. This will ensure the eyes are not affected by the glare from the sun or snow.
At no time should the goggles be used to help assess the visibility.
They were invented by Wilhelm Trendelenburg in 1916.〔(Red Goggles (ca. 1940s) )〕
== Concept ==
The concept is based on the work by Antoine Béclère on dark adaptation of the eye, where it is noted that fluoroscopy relies on the use of the retinal rods of the eye.
Since retinal rods are insensitive to long wavelengths of light, such as red light, while retinal cones are not, the goggles enabled the physicians to adapt their eyes in preparation for the fluoroscopic procedure while still being able to perform other work.
Prior to the invention of these goggles, physicians were required to sit in the darkened room where the procedure would be performed for extended periods to adapt their eyes to the low lighting conditions.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Dark adaptor goggles」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.